Technical information
Table Of Contents
- PART1.pdf
- PART2.pdf
- OPERATION OF THE EQ 55
- BASIC OPERATION OF THE EQ 55
- MENU SELECTIONS
- DISPLAY MODE MENU
- EXPANSION MENU
- GAIN MENU
- TRANSMIT POWER MENU
- CONFIGURATION MENU
- Configuration- Units of Measure
- Configuration - Background Color
- Configuration - Language
- Configuration - EXT I/F (External Interface) Sub-menu
- Configuration - EXT I/F - NMEA 0183
- Configuration - EXT I/F - Printer
- Configuration - EXT I/F - Ship's Speed
- Configuration - EXT I/F - Water Temperature
- Configuration - EXT I/F - Trigger
- Configuration - Test Pattern
- Configuration - TVG (Time Varying Gain)
- Configuration - Color Threshold
- Configuration - Scroll Speed
- Configuration - Alarms Sub-menu
- Configuration - Alarms - Set Min Depth (Set Minimum Depth)
- Configuration - Alarms - Set Max Depth (Set Maximum Depth)
- Configuration - Alarms - Min and Max Alarms ON/OFF
- Configuration - White Line
- Configuration - Filter
- Configuraiton - STC (Sensitivity Time Control)
- Configuration - Depth Adjust (Depth Adjustment)
- Configuration - Sound Velocity
- Configuration - Save Settings
- Configuration - Load Settings
- OPERATION OF THE EQ 55
- PART3.pdf
- PART4.pdf
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- BASIC INFORMATION
- TRANSDUCERS AND SPEED/TEMPERATURE SENSORS
- DETERMINING THE POSITION FOR THE TRANSDUCER
- General
- Go Deep
- The Boundary Water Layer
- Propeller Noise
- Vessel Heave
- Noise From Protruding Objects on the Hull
- Summing up on Transducer Location
- Thru-hull Installation
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull.
- Adapter plate for EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- Steel Stuffing Tube for EQ 55 Standard Transducer.
- DISPLAY UNIT INSTALLATION
- ELECTRICAL CONNECTIONS
- Power Supply Connections
- Fuse
- Cabinet Grounding
- Rear Panel Receptacles
- Speed and Temperature Sensor Connections
- NMEA 0183 Interface Connections
- Color Printer Connection
- Location of Fuse and Rear Panel Receptacles
- Transducer Connectors ( European)
- Transducer Connectors ( North American )
- Speed Temperature Connectors
- NMEA Connectors
- MOUNTING BRACKET ASSEMBLY DRAWING
- OUTLINE & INSTALLATION DRAWING - EQ55 ECHO SOUNDER
- OUTLINE & INSTALLATION DRAWING - EQ55SA ECHO SOUNDER
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- PART5.pdf
- PART6.pdf
- PART7.pdf
- PART8.pdf
- PARTA.pdf
- PARTB.pdf

950-7001001/Iss 1.2 EQ-55 Operators Manua
l
Page 2.26 Operation of the EQ-55
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
2.6 TRANSMIT POWER MENU
Selection of the Transmit Power function from the
Main Menu allows for the adjustment of the level of
energy being output.
Note: The transmit power is the same on both HIGH
and LOW Frequency channels.
HIGH: Full power, 1000 watts per channel
MED: 100 watts per channel
LOW: 10 watts per channel
OFF: No transmission
Generally speaking, High Power is most useful in
deeper water and Low Power is more useful in very
shallow water.
MAIN MENU
LF SETTING
HF SETTING
DISPLAY MODE
EXPANSION
SET MARKER
GAIN
TRANSMIT POWER
CONFIGURATION
↓
↓↓
↓
POWER
HIGH
MED
LOW
OFF