Technical information
Table Of Contents
- PART1.pdf
- PART2.pdf
- OPERATION OF THE EQ 55
- BASIC OPERATION OF THE EQ 55
- MENU SELECTIONS
- DISPLAY MODE MENU
- EXPANSION MENU
- GAIN MENU
- TRANSMIT POWER MENU
- CONFIGURATION MENU
- Configuration- Units of Measure
- Configuration - Background Color
- Configuration - Language
- Configuration - EXT I/F (External Interface) Sub-menu
- Configuration - EXT I/F - NMEA 0183
- Configuration - EXT I/F - Printer
- Configuration - EXT I/F - Ship's Speed
- Configuration - EXT I/F - Water Temperature
- Configuration - EXT I/F - Trigger
- Configuration - Test Pattern
- Configuration - TVG (Time Varying Gain)
- Configuration - Color Threshold
- Configuration - Scroll Speed
- Configuration - Alarms Sub-menu
- Configuration - Alarms - Set Min Depth (Set Minimum Depth)
- Configuration - Alarms - Set Max Depth (Set Maximum Depth)
- Configuration - Alarms - Min and Max Alarms ON/OFF
- Configuration - White Line
- Configuration - Filter
- Configuraiton - STC (Sensitivity Time Control)
- Configuration - Depth Adjust (Depth Adjustment)
- Configuration - Sound Velocity
- Configuration - Save Settings
- Configuration - Load Settings
- OPERATION OF THE EQ 55
- PART3.pdf
- PART4.pdf
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- BASIC INFORMATION
- TRANSDUCERS AND SPEED/TEMPERATURE SENSORS
- DETERMINING THE POSITION FOR THE TRANSDUCER
- General
- Go Deep
- The Boundary Water Layer
- Propeller Noise
- Vessel Heave
- Noise From Protruding Objects on the Hull
- Summing up on Transducer Location
- Thru-hull Installation
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull.
- Adapter plate for EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- Steel Stuffing Tube for EQ 55 Standard Transducer.
- DISPLAY UNIT INSTALLATION
- ELECTRICAL CONNECTIONS
- Power Supply Connections
- Fuse
- Cabinet Grounding
- Rear Panel Receptacles
- Speed and Temperature Sensor Connections
- NMEA 0183 Interface Connections
- Color Printer Connection
- Location of Fuse and Rear Panel Receptacles
- Transducer Connectors ( European)
- Transducer Connectors ( North American )
- Speed Temperature Connectors
- NMEA Connectors
- MOUNTING BRACKET ASSEMBLY DRAWING
- OUTLINE & INSTALLATION DRAWING - EQ55 ECHO SOUNDER
- OUTLINE & INSTALLATION DRAWING - EQ55SA ECHO SOUNDER
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- PART5.pdf
- PART6.pdf
- PART7.pdf
- PART8.pdf
- PARTA.pdf
- PARTB.pdf

950-7001001/Iss 1.2 EQ-55 Operators Manua
l
Page 2.12 Operation of the EQ-55
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
2.2.8 Low or High Frequency - Set VRM (Variable Range Marker)
Set VRM places a horizontal white line at a selected
location. The use of a VRM allows you to measure
the depth to any displayed target.
Use the joystick to highlight SET VRM, then press
the joystick to the right to make the selection. Now,
moving the joystick up or down will move the white
VRM line, and the VRM depth will be shown in the
STATUS window.
MAIN MENU
LF SETTING
HF SETTING
DISPLAY MODE
EXPANSION
SET MARKER
GAIN
TRANSMIT POWER
CONFIGURATION
↓
↓↓
↓
LF SETTINGS
MANUAL RANGE
MANUAL PHASE
AUTO RANGE OFF
AUTO PHASE
SET VRM
LF VRM
Ù
Ú
STATUS