Technical information
Table Of Contents
- PART1.pdf
- PART2.pdf
- OPERATION OF THE EQ 55
- BASIC OPERATION OF THE EQ 55
- MENU SELECTIONS
- DISPLAY MODE MENU
- EXPANSION MENU
- GAIN MENU
- TRANSMIT POWER MENU
- CONFIGURATION MENU
- Configuration- Units of Measure
- Configuration - Background Color
- Configuration - Language
- Configuration - EXT I/F (External Interface) Sub-menu
- Configuration - EXT I/F - NMEA 0183
- Configuration - EXT I/F - Printer
- Configuration - EXT I/F - Ship's Speed
- Configuration - EXT I/F - Water Temperature
- Configuration - EXT I/F - Trigger
- Configuration - Test Pattern
- Configuration - TVG (Time Varying Gain)
- Configuration - Color Threshold
- Configuration - Scroll Speed
- Configuration - Alarms Sub-menu
- Configuration - Alarms - Set Min Depth (Set Minimum Depth)
- Configuration - Alarms - Set Max Depth (Set Maximum Depth)
- Configuration - Alarms - Min and Max Alarms ON/OFF
- Configuration - White Line
- Configuration - Filter
- Configuraiton - STC (Sensitivity Time Control)
- Configuration - Depth Adjust (Depth Adjustment)
- Configuration - Sound Velocity
- Configuration - Save Settings
- Configuration - Load Settings
- OPERATION OF THE EQ 55
- PART3.pdf
- PART4.pdf
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- BASIC INFORMATION
- TRANSDUCERS AND SPEED/TEMPERATURE SENSORS
- DETERMINING THE POSITION FOR THE TRANSDUCER
- General
- Go Deep
- The Boundary Water Layer
- Propeller Noise
- Vessel Heave
- Noise From Protruding Objects on the Hull
- Summing up on Transducer Location
- Thru-hull Installation
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull.
- Adapter plate for EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- Steel Stuffing Tube for EQ 55 Standard Transducer.
- DISPLAY UNIT INSTALLATION
- ELECTRICAL CONNECTIONS
- Power Supply Connections
- Fuse
- Cabinet Grounding
- Rear Panel Receptacles
- Speed and Temperature Sensor Connections
- NMEA 0183 Interface Connections
- Color Printer Connection
- Location of Fuse and Rear Panel Receptacles
- Transducer Connectors ( European)
- Transducer Connectors ( North American )
- Speed Temperature Connectors
- NMEA Connectors
- MOUNTING BRACKET ASSEMBLY DRAWING
- OUTLINE & INSTALLATION DRAWING - EQ55 ECHO SOUNDER
- OUTLINE & INSTALLATION DRAWING - EQ55SA ECHO SOUNDER
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- PART5.pdf
- PART6.pdf
- PART7.pdf
- PART8.pdf
- PARTA.pdf
- PARTB.pdf

950-7001001/Iss 1.2 EQ-55 Operators Manua
l
Page 2.8 Operation of the EQ-55
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
2.2.4 Low or High Frequency - Manual Phase
The phased range allows you to view a selected
"window" below your vessel. The "manual" range
(set above) determines the vertical size of the
"window." The "phase" range determines the
depth of the upper edge of the " window."
The selection window displays the "start" range.
The range can be changed by moving the joystick
up or down. Once the correct range is shown in
the selection window, press the joystick to the right
to make your selection.
MAIN MENU
LF SETTING
HF SETTING
DISPLAY MODE
EXPANSION
SET MARKER
GAIN
TRANSMIT POWER
CONFIGURATION
↓
↓↓
↓
LF SETTINGS
MANUAL RANGE
MANUAL PHASE
AUTO RANGE OFF
AUTO PHASE OFF
SET AUTO PHASE
SET VRM
PHASE
40
Ù
0
Ú
0
STATUS