Technical information
Table Of Contents
- PART1.pdf
- PART2.pdf
- OPERATION OF THE EQ 55
- BASIC OPERATION OF THE EQ 55
- MENU SELECTIONS
- DISPLAY MODE MENU
- EXPANSION MENU
- GAIN MENU
- TRANSMIT POWER MENU
- CONFIGURATION MENU
- Configuration- Units of Measure
- Configuration - Background Color
- Configuration - Language
- Configuration - EXT I/F (External Interface) Sub-menu
- Configuration - EXT I/F - NMEA 0183
- Configuration - EXT I/F - Printer
- Configuration - EXT I/F - Ship's Speed
- Configuration - EXT I/F - Water Temperature
- Configuration - EXT I/F - Trigger
- Configuration - Test Pattern
- Configuration - TVG (Time Varying Gain)
- Configuration - Color Threshold
- Configuration - Scroll Speed
- Configuration - Alarms Sub-menu
- Configuration - Alarms - Set Min Depth (Set Minimum Depth)
- Configuration - Alarms - Set Max Depth (Set Maximum Depth)
- Configuration - Alarms - Min and Max Alarms ON/OFF
- Configuration - White Line
- Configuration - Filter
- Configuraiton - STC (Sensitivity Time Control)
- Configuration - Depth Adjust (Depth Adjustment)
- Configuration - Sound Velocity
- Configuration - Save Settings
- Configuration - Load Settings
- OPERATION OF THE EQ 55
- PART3.pdf
- PART4.pdf
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- BASIC INFORMATION
- TRANSDUCERS AND SPEED/TEMPERATURE SENSORS
- DETERMINING THE POSITION FOR THE TRANSDUCER
- General
- Go Deep
- The Boundary Water Layer
- Propeller Noise
- Vessel Heave
- Noise From Protruding Objects on the Hull
- Summing up on Transducer Location
- Thru-hull Installation
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull
- EQ 55 Standard Transducer Mounted to Wood or Fiberglass Hull.
- Adapter plate for EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- EQ 55 Standard Transducer Mounted to a Steel Hull.
- Steel Stuffing Tube for EQ 55 Standard Transducer.
- DISPLAY UNIT INSTALLATION
- ELECTRICAL CONNECTIONS
- Power Supply Connections
- Fuse
- Cabinet Grounding
- Rear Panel Receptacles
- Speed and Temperature Sensor Connections
- NMEA 0183 Interface Connections
- Color Printer Connection
- Location of Fuse and Rear Panel Receptacles
- Transducer Connectors ( European)
- Transducer Connectors ( North American )
- Speed Temperature Connectors
- NMEA Connectors
- MOUNTING BRACKET ASSEMBLY DRAWING
- OUTLINE & INSTALLATION DRAWING - EQ55 ECHO SOUNDER
- OUTLINE & INSTALLATION DRAWING - EQ55SA ECHO SOUNDER
- INSTALLATION INSTRUCTIONS FOR THE EQ 55.
- PART5.pdf
- PART6.pdf
- PART7.pdf
- PART8.pdf
- PARTA.pdf
- PARTB.pdf

950-70017001/Iss 1.2 EQ-55 Operators Manua
l
Page 4.22 Installation Instructions for the EQ-55
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
4.4 DISPLAY UNIT INSTALLATION
The display unit is designed to function normally on a continuous basis in the high
humidity of a marine environment. However, to ensure the long term
performance and reliability of the display unit, it should be installed in a dry, well
ventilated location. Avoid installation in areas where heavy shocks or vibrations
are expected or where the unit will be exposed to high temperatures.
Using the mounting bracket the EQ 55 Display Unit may be "table top" mounted
(see Figure 4.14) or the EQ 55 may be mounted to the ceiling
The EQ 55 may also be recess mounted into a control console and rack mounted.
Be sure that there is no tension applied to the cabling when the installation is
complete.
Choose a mounting surface that is strong enough to support the cabinet weight (60
pounds/27 kg) under extreme operating conditions. Reinforce the mounting
surface if necessary.
Provide sufficient clearance around the cabinet to allow free circulation of air and
to gain access to the connectors and fuse. Do not block the sides, bottom or rear
panel of the cabinet or overheating will occur.
The display unit can be mounted on a table top, bulkhead or over head by using
the supplied mounting bracket. See mounting hole pattern drawing, Figure 4.15.
WARNING: CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY SIMRAD MESOTECH LTD MAY VOID YOUR WARRANTY
AND MAY CAUSE INCREASED RADIO FREQUENCY EMISSIONS. THE
EQ 55 IS A SOPHISTICATED PIECE OF ELECTRONIC EQUIPMENT,
DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH GOOD
ENGINEERING PRACTICES. IT SHOULD BE REALIZED, HOWEVER,
THAT THE POSSIBILITY OF INTERFERENCE WITH OTHER
EQUIPMENT, PARTICULARLY COMMUNICATIONS EQUIPMENT,
EXISTS. CAREFUL ATTENTION TO CABLING, ADEQUATE
SEPARATION AND SHIELDING IS REQUIRED DURING AND AFTER
INSTALLATION TO ENSURE BEST RESULTS.