Instruction manual

Instruction manual
20220513E 75
26
24
22
20
18
16
14
12
10
8
6
4
2
0
H
I
s
p
e
e
d
p
a
r
a
m
e
t
e
r
s
L
O
s
p
e
e
d
p
a
r
a
m
e
t
e
r
s
Transition Speed set to 9 Knots
Example of
Transition speeds with
AUTOMATIC Speed parameter
selection
Transition to HI parameters
with increasing speed: 10 Knots
Transition to LO parameters
with decreasing speed: 8 Knots
Press MODE to activate the transition speed setting. The
display will start flashing. Use < or > to set the speed value
and store the value by pressing MODE. Push > to proceed
to next menu item.
If automatic HI/LO parameter selection is not wanted, leave
SPEED at zero.
Master Reset
Note ! A Master Reset is part of the final test at factory and will
reset the memories to factory settings. Unless you need to
clear all stored values during the installation setup
procedure, you should not perform a Master Reset.
The RESET function is activated by pressing MODE. You
then will have to select YES by pressing the > button and to
acknowledge YES by pressing the MODE button.
During normal installation set-up, the RESET menu item is
omitted by another push on the > button to proceed to the
SEA SET menu display.