Instruction manual

Robertson AP11 Autopilot
58 20220513E
TB6
J3000X/J300X JUNCTION UNIT
POWER PCB
TB3 TB4
TB5
TB7
Stbd
Port
Gnd
Gn
Red Blu
REMOTE
TB8
TB1
TB2
R3000X
REMOTE CONTROL
Lamp
Yel
Figure 28 R3000X connection
3.12 S100 NFU Lever installation
The S100 Steering Lever is for indoor mounting in panels up
to 8 mm (5/16") tick. The handle has to be removed from the
unit before mounting. A 22 mm (7/8" hole should be cut in
the panel. Be sure that the Robertson label is pointing
forward to get correct direction of rudder movement
(Port/Stbd.) when operating the steering lever. S100 is
supplied with 2m (6,7') cable and plug. Cut the plug and
connect the wires to the junction unit Power PCB as shown.
An optional extension cable is available from Simrad
Robertson. Alternatively a suitable cable and junction box or
terminal should be provided locally.
TB6
JUNCTION UNIT
POWER PCB
TB3 TB4
TB5
TB7
S100
NFU
STEERING LEVER
Stbd
Port
Gnd
Gn
Red
Blu
REMOTE
TB1
TB2
Figure 29 S100 connection