Instruction manual

Instruction manual
20220513E 57
MAIN CONTROL UNIT
Bus
Bus +
Vsys+
Vsys
On-Off
Alarm
Bn
Wh
Gry
Yel
Gn
GREY
BROWN
PINK
WHITE
RFC35R
RATE COMPASS
GREY
BROWN
GREEN
PINK
YELLOW
WHITE
DO NOT
CONNECT!
DO NOT
CONNECT!
ALTERNATIVE CONNECTION
J3000X/J300X JUNCTION UNIT
REAR SIDE
MAIN PCB
Pnk
NOTE
ROBNET
Figure 27 RFC35R Rate Compass connection
Note ! Refer to page 55; screen connection.
Select “net” in the Dockside menu. Refer to page 70
Perform the compass calibration as described on page
78.
Note ! After turn on the compass will stabilize in less than 30
seconds, but it will need another 10 minutes to get the
full effect of the rate sensor.
Refer to page 78 to compensate for any permanent off-set
after the calibration is completed.
RFC35R calibration data is stored in the compass and will
not be deleted by a Master Reset in the autopilot. Offset
corrections, however, must be reset.
3.11 R3000X Remote Control installation
R3000X should be mounted in the supplied bracket that can
be fixed by four mounting screws. The unit is not
waterproof and should be protected when mounted
outdoor.