Manual selection of Sea State Filter
Press and hold both the
and the Mode button
(From any mode)
STBY -AUTO
PWR
RESPONSE TURN
MODE
DODG E
AUTOPILOT
ROBERTSON AP11
Rudder
STBY-AUTO
PWR
RESPONSE TURN
MODE
DODGE
AUTOPILOT
ROBERTSON AP11
Rudder
Select filter setting using < (decreasing) or > (increasing).
Filter setting Description
OFF Tightest steering. Most active rudder.
AUTO Automatically sets autopilot sensitivity
according to sea state (adaptive).
1 Lowest yaw band value that can be set
manually.
10 Highest yaw band value that can be set
manually (max. damping).
The AP11 will return to active mode by pressing the
STBY/AUTO button, or it automatically times out after 30
seconds and returns to active mode.
Sea State Filter setting is stored in the autopilot memory
when power is turned off and is recalled next time the
system is used.