Instruction manual
Simrad EK60
54
850-164696 / A
C25 - Temperature sensor
This is an input to provide water temperature from an external
sensor. This functionality is however not currently supported by
the EK60 software.
C26 - Digital ground
Use this for signal grounding.
→ Cable details on page 70.
C27 - Ship’s ground
Use this for EMC grounding.
→ Cable details on page 70.
C28 - AC Power
This is the AC power connection for the entire cabinet.
→ Cable details on page 70.
C29 - DC output
DC outputs are available from the internal power supply.
→ Cable details on page 70.
C30A / C30B - Transducers
The transducer cable is fixed to the transducer. The standard
transducer cable supplied is 20 meters long.
Note The transducer cable between the transducer and the GPT
Cabinet must be run in steel conduits. Use flexible conduit close
to the plug on the transceiver.
→ Cable details on page 76.
Using more than one GPT Cabinet
If more than one GPT Cabinet is used remember the following:
• Seperate synchronisation to each cabinet.
• Remote is normally connected in parallell, but that is eligible.
• The motion sensor is connected to one GPT Cabinet only.
• The temperature sensor is connected to one GPT Cabinet
only.
• The “New line in” is connected to one GPT Cabinet only.
• The “Event in” is connected to one GPT Cabinet only.