Cable layout
51
850-164696 / A
C26 - AC Power to Ethernet Switch
Several types of switches are available. Some have internal
power supplies, other rely on small external power supplies.
→ Cable details on page 62.
C27 - EMC ground
Each of the General Purpose Transceivers (GPT) must be
connected to the ship’s ground.
→ Cable details on page 63.
C28 - AC Power
These are the AC power cables for the GPTs.
→ Cable details on page 62.
C29 - +12 Vdc
The optional +12 Vdc input/output connector, one for each GPT.
For simplicity, these have been omitted from the cable drawing.
→ Cable details on page 64.
C30 - Transducer
The transducer cable is fixed to the transducer. The standard
transducer cable supplied is 20 meters long.
Note The transducer cable between the transducer GPT must be run
in steel conduits. Use flexible conduit close to the plug on the
transceiver.
→ Cable details on page 76.