Installation manual
GPT transducer terminations
50/200 Combi C transducer
This is the termination of the transducer cable from the 50/200
Combi C transducer. The transducer cable is terminated
in a Multi-Con-X connector manufactured by Conxall
(w
ww.conxall.com). The other end of the cable is permanently
fixed to t he transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Multi-Con-X
connector
"Multi-Con-X" provided by www.conxall.com
Note: The transducer cable must not be exposed
to oil or other petroleum fluids.
H
C
J
D
4
17
Connection box
with Multi-Con-X socket
"Auxiliary" 25-pin
D-connector on GPT
GPT Transducer
socket
Screen to plug housing
W802-12
Rev.A
50/200 Combi C transducer, termination
3
3
1
1
6
6
5
5
4
4
2
2
7
7
50 kHz
50 kHz
50 kHz
50 kHz
200 kHz
200 kHz
200 kHz
200 kHz
Thermistor
Thermistor
Thermistor
Thermistor
Red
Black
Blue
White
Green
Yellow
Screen
3
1
6
5
4
2
7
A small circular marker identifies pin 1.
(1)
(2)
(3)
(6)
(7)
(4)
(5)
View: Looking the socket on the rear side of the cabinetinto
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the “dry part” of the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
851-160164/H 63