Installation manual
GPT transducer terminations
ES38–10 transducer
This is the termination of the transducer cable from the ES38–10
split-beam transducer to the t ransducer socket on the ES60 and
EK60 General Purpose Transceiver Unit (GPT). The other end of
the cable is permanently fixed to the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
ES38-10
transducer cable
J
E
F
H
D
C
Junction Box (1:1)
(Optional)
GPT Transducer
socket
White
White
White
Black
Black
Black
Screen Connect to plug housing
W802-8
Rev.A
ES38-10 Transducer cable termination
FWD
Sections seen from top
of the transducer
1
2
3
1
2
3
There are four pairs in the transducer cable, each with one black
and one white cable. Each pair is marked with a small label
identifying the transducer section. Pair number 4 is not used.
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.