Installation manual
Simrad Echo sounder transducers
Split beam transducer to single beam transceiver
This is the termination of the transducer cable from a single
frequency, split beam transducer - wired as a single beam
transducer - to the socket on the General Purpose Transceiver
Unit (GPT). The other end of the cable is permanently fixed to
the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
C
D
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Connect to plug housing
W802-5
Rev.E
Single frequency, split beam connected as single beam
Forward
Starboard
Port
Sections seen from top
of the transducer
2
1
3
4
21
3
4
White
Blue
White
Blue
Blue
Orange
Green
Brown
White
White
White
White
White
Blue
White
Blue
Black
Black
Black
Black
Black
Black
Black
Black
Screen
Alternative cable
colours
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
56
851-160164/H