Installation manual
Simrad Echo sounder transducers
Single beam, normal power transducer
This is the termination of the transducer cable from a single
frequency, single beam t ransducer to the transducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently fixed to the transducer.
Normal power output is achieved when the GPT is equipped with
a single transmitter board.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
D
C
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Screen
Drain wire
Connect to plug housing
W802-1
Rev.E
Single frequency, single beam, normal power termination
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
52