Installation manual
| 31
Wiring | AP70/AP80 Installation Manual
Current feedback input
Connects to: SD80 board (in SD80, AC80S or AC85 Computer) or AD80 board (in AD80,
AC80S or AC85 Computer).
COM
I_IN
U_IN
RUD_UI
U_IN RANGE
+20V
+10V
+5V
AD80/SD80,
AC80S or AC85
Computer
AD80/SD80 BOARDCURRENT FEEDBACK INPUT
COM
4 - 20 mA
I_IN
External feedback pot.meter input
Connects to: SD80 board (in SD80, AC80S or AC85 Computer) or AD80 board (in AD80,
AC80S or AC85 Computer).
AD80/SD80,
AC80S or AC85
Computer
AD80/SD80 BOARDEXTERNAL FEEDBACK
POT.METER INPUT
FRQ +
FRQ
-
RET
RUD_FRQ
RUD_UI
COM
I_IN
U_IN
FRQ +
RET
COM
U_IN
External voltage feedback input
Connects to: SD80 board (in SD80, AC80S or AC85 Computer) or AD80 board (in AD80,
AC80S or AC85 Computer).
COM
I
_
IN
U_IN
RUD_UI
U_IN RANGE
+20V
+10V
+5V
External
feedback
signal
AD80/SD80,
AC80S or AC85
Computer
AD80/SD80 BOARD
EXTERNAL VOLTAGE INPUT
COM
U_IN
The DIP switch must be set to match range for analog voltage input signal.
U_IN RANGE
+20V
+10V
+5V