Extra Information

16 |
AP70/AP80 | Addendum for sw release 1.2
External feedback pot.meter input
Page 31.
Added missing potentiometer value and dip switch setting.
Connects to: SD80 board (in SD80, AC80S or AC85 Computer) or AD80 board (in AD80,
AC80S or AC85 Computer).
AD80/SD80,
AC80S or AC85
Computer
AD80/SD80 BOARD
EXTERNAL FEEDBACK
POT.METER INPUT
(1-10 K)
FRQ +
FRQ -
RET
RUD_FRQ
RUD_UI
COM
I_IN
U_IN
FRQ +
RET
COM
U_IN
U_IN RANGE
+20V
+10V
+5V
External Take command
Page 32.
Wrong wiring (left side of switch wired to red wire instead of black).
An external take command signal
can be used to take command on a
control unit.
The function is identical to a short
press on the CMD key on the AP70
and AP80 control unit.
In an open system (no command
transfer restrictions) you will get
immediate control from the control
unit requesting command.
In a multi-station system with active
lock function, the command request
must be confirmed on the active
control unit.
Key Color Description
1 Black Battery (-)
2 Blue Alarm/Active
3 Yellow External command
4 Red Battery (+), 12 - 24 V DC
PART OF
STATION
SELECTOR
12 - 24 V DC
+
_
1
4
3
2
4
1 8
3
2
1