Operation Manual

Simrad AP20 Autopilot
86 20220505H
Refer to the drive unit table on page 58 for information. It is not
possible to select a higher voltage than the input voltage. The
CLUTCH/BYPASS voltage is automatically set to the same as
the drive unit voltage. In Rudder Test, the AP20 system will
automatically detect whether the drive unit is a reversible motor
or solenoid operated.
Dockside
Boat type Planing
Drive unit voltage ---
Rudd feedb cal STBD ---
Rudd feedb cal PORT ---
Rudder test ---
--------- drive
Clutch ------
Transition speed 00kn
12V
24V
To change the voltage selection, rotate the course knob.
Note ! The drive unit voltage setting does not apply when operating
solenoids on a continuous running pump/steering gear. Hence,
the output voltage to the solenoids will be the same as the input
voltage.
Proceed to next menu item by pressing STBD [>] button.
Rudder Feedback Calibration
Make sure the RF300 is installed and aligned as pr. instruction in
section 4.6 (or eventually section 4.27 for LF3000). This
function enables you to compensate for any non-linearity in the
transmission between the rudder and the rudder feedback.
Dockside
Boat type Planing
Drive unit Voltage 12V
Rudd feedb cal STBD ---
Rudd feedb cal PORT ---
Rudder test ---
-------- drive
Clutch ------
Transition speed 00kn
No
Yes
Confirm by rotating the course knob clockwise.