Installation manual

Interfacesandintegration
5IntheSelectInputsdialog,locatetheAMLontheleftside,andclickthe[>]button
toconnectit.
Thissettingallowsyoutocommunicatewiththemotionsensorsystem.
Thefollowingproprietarytelegramformatsaresupported:
Sounder/TSS1Motionprotocolonpage173
SimradEMAttitude1000onpage168
SimradEMAttitude3000onpage169
6ClickOKtosavethecurrentsettingsandclosethedialog.
7IntheI/OSetupdialog,clickonthechosenporttoselectit,thenclicktheSetup
buttontoopentheSerialSetupdialog.
8IntheSerialSetupdialog,entertherelevantparameterstosetuptheport.
9ClickOKtosavethecurrentsettingsandclosethedialog.
10IntheI/OSetupdialog,clickonthechosenporttoselectit,thenclicktheMonitor
buttontoopenthePortMonitordialog.
Inordertomonitorthedataow,themotionsensorsystemmustbeactiveand
transmittinginformationtotheES70.
11Ifthedataowisoperational,closealldialogs.
Howtosetupthedepthoutput
TheES70Fishndingechosounderwilloutputdepthinformationonseveraldifferent
formats.
Supportedtelegramformats
DBSDepthbelowsurfaceonpage161
DBTDepthbelowtransduceronpage162
DPTDepthonpage162
SimradEK500Depthonpage167
Atlasdepthtelegramonpage175
PSIMDHBBottomhardnessandbiomassonpage172
Wiringprocedureforserialcommunication
1LocatewhichRS-232portyouwishtouse.
2TheES70Fishndingechosounder,connectthetransmitsignalTxonpin3,and
groundonpin5.
GenericRS-232Seriallineonpage42
3Ontheremotesystem,wireasdescribedintherelevantdocumentation.
4Ensurethatthelengthofthecabledoesnotexceedapproximately50meters.Ifa
longercableisrequired,youmayneedtousebufferampliersontheserialline.
343522/A
93