Installation manual

SimradES70
5IntheSelectInputsdialog,locatetheITIontheleftside,andclickthe[>]button
toconnectit.
ITI:ThissettingallowsyoutocommunicatewiththeSimradITIsystem.
ValuesfortrawlopeninganddistancemustbeenteredmanuallyintheTrawl
dialog.
Thefollowingproprietarytelegramformatsaresupported:
DBSDepthbelowsurfaceonpage161
DBSDepthoftrawlbelowsurfaceonpage170
HFBTrawlheadropetofootropeandbottomonpage170
6ClickOKtosavethecurrentsettingsandclosethedialog.
7IntheI/OSetupdialog,clickonthechosenporttoselectit,thenclicktheSetup
buttontoopentheSerialSetupdialog.
8IntheSerialSetupdialog,entertherelevantparameterstosetuptheport.
9ClickOKtosavethecurrentsettingsandclosethedialog.
10IntheI/OSetupdialog,clickonthechosenporttoselectit,thenclicktheMonitor
buttontoopenthePortMonitordialog.
Inordertomonitorthedataow,theITIsystemmustbeactiveandtransmitting
informationtotheES70.
11Ifthedataowisoperational,closealldialogs.
HowtosetuptheSimradPICatchmonitoringsystem
interface
CommunicationwiththeSimradPIFamilycatchmonitoringsystemsisbasedonNMEA
andproprietarytelegrams.
Supportedtelegramformats
DBSDepthbelowsurfaceonpage161
PSIMP .DPISensordataonpage171
Wiringprocedureforserialcommunication
1LocateafreeRS-232serialportthatcanbeusedtoconnectthePIsystem.
2OntheES70computer,connectthereceivesignalRxonpin2,thetransmitsignal
Txonpin3,andgroundonpin5.
GenericRS-232Seriallineonpage42
3OnPI44andPI54,useeitherconnectorNMEA1orNMEA2.Connectthereceive
signalRxonpin8,thetransmitsignalTxonpin6,andgroundonpins7and9.
PI44/54seriallineonpage61
4OnPI30andPI32,useconnectorNMEA.ConnectthereceivesignalRxonpin3,the
transmitsignalTxonpin1,andgroundonpins2and4.
PI30/32seriallineonpage62
88