Installation manual
ES70Cablelayout
Singlebeamtransducertosplitbeamtransceiver
Thisistheterminationofthetransducercablefromasinglefrequency,singlebeam
transducertothesocketonasplitbeamGeneralPurposeTransceiverUnit(GPT).The
otherendofthecableispermanentlyxedtothetransducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
E
A
B
C
D
H
J
F
JunctionBox(1:1)
(Optional)
GPT Transducer
socket
Screen Connecttoplughousing
W802-9
Rev.A
Singlefrequency ,singlebeam,tosplitbeamtransceiver ,termination
Ifyouneedtosplicethetransducercable,itisveryimportanttousethecorrectcable,
andtoavoidgroundloops.Westronglyrecommendtheuseofajunctionbox.Wealso
recommendthatyouinstallthetransducercableinasteelconduit.
Formoreinformation,see:
•Transducercablesplicingonpage142
•Steelconduitonpage142
•GPTTransducerplugconnectiononpage107
343522/A
71










