Installation manual

SimradES70
GPTtrigger/synchronisation
ThiscableisusedtoconnecttheGeneralPurposeTransceiver(GPT)toanexternal
systemforsynchronisationpurposes.Itconnectstothe25–pinD-subconnectoron
thefrontsideoftheGPT.
25
GPT
25-pinD-subconnector
24
13
12
TrigOut(+)
TrigOut(-)
TrigIn(+)
TrigIn(-)
SIMRAD GPT
25
14
1
13
Auxiliary
connector
(female)
Thecablescreenisconnectedtotheplughouse.
W620B
Rev.D
Synchronisation/Externaltrigger
Cablespecications
Conductors:2x2x0.22mm²
Screen:Braidedpairsandoverallbraided
V oltage:60V
Maximumdiameter:Denedbytheplugs
58
343522/A