Installation manual
SimradES70
Physicalandenvironmentalspecications
•Connectors:
–Transducer:12-pinfemaleAmphenol,ShellMS3102A-24,Insert24-19S
–AUI:15-pinfemaleDelta(seebelow)
–Network:8-pinRJ-45socket
–Auxiliary:25-pinfemaleDelta
•AUIConnector:
–Analoginputforheave,rollandpitch
–Digitaltriggerin/out
–Alarmoutput
–+12Vdcoutput(maximum100mA)
––12Vdcoutput(maximum100mA)
–+5Vdcoutput(maximum200mA)
•Physicaldimensions:
–Width:284mm
–Height:112mm
–Depth:246mm
–Seealso:GPTOutlinedimensionsonpage102
•Weight:
–Withonetransmitterboard:2.7kg
–Withtwotransmitterboards:3.3kg
–Withthreetransmitterboards:4.5kg
•Standardsupplypower:
–ACoperation:95to265V ac,50-60Hz,50-100W
–DCoperation:11to15Vdc,50-100W
•Externalpowersupplyforspeciccongurations:
–ACinput:230V ac,50–60Hz
–DCoutput:13.2Vdc,10A
–Physicalsize(excludingmountingbrackets)(WDH):110x190x54mm
–Seealso:GPTPowersupplyoutlinedimensionsonpage104
•Fuses:
–ACfuse:Ø5x20mm,2Aslow
–DCfuse:Ø5x20mm,10Asloworfast
•Operationaltemperature:0to+55°C
•Storagetemperature:-40to+70°C
•Humidity:5to95%relativenon-condensing
110