Installation manual

SimradES70
Physicalandenvironmentalspecications
Connectors:
Transducer:12-pinfemaleAmphenol,ShellMS3102A-24,Insert24-19S
AUI:15-pinfemaleDelta(seebelow)
Network:8-pinRJ-45socket
Auxiliary:25-pinfemaleDelta
AUIConnector:
Analoginputforheave,rollandpitch
Digitaltriggerin/out
Alarmoutput
+12Vdcoutput(maximum100mA)
–12Vdcoutput(maximum100mA)
+5Vdcoutput(maximum200mA)
Physicaldimensions:
Width:284mm
Height:112mm
Depth:246mm
Seealso:GPTOutlinedimensionsonpage102
Weight:
Withonetransmitterboard:2.7kg
Withtwotransmitterboards:3.3kg
Withthreetransmitterboards:4.5kg
Standardsupplypower:
ACoperation:95to265V ac,50-60Hz,50-100W
DCoperation:11to15Vdc,50-100W
Externalpowersupplyforspeciccongurations:
ACinput:230V ac,50–60Hz
DCoutput:13.2Vdc,10A
Physicalsize(excludingmountingbrackets)(WDH):110x190x54mm
Seealso:GPTPowersupplyoutlinedimensionsonpage104
Fuses:
ACfuse:Ø5x20mm,2Aslow
DCfuse:Ø5x20mm,10Asloworfast
Operationaltemperature:0to+55°C
Storagetemperature:-40to+70°C
Humidity:5to95%relativenon-condensing
110