Specification

The RTUD ratcheting take-up device is a cost-effective shrinkage
compensation solution for continuous rod systems. The RTUD is
now code-listed for use with rod systems to ensure highly reliable
performance in a device that allows for unlimited shrinkage.
Once the RTUD is installed, a series of internal threaded wedges
enable the device to ratchet down the rod as the wood structure
shrinks, but engage the rod in the reverse direction when
under tensile loading. Continuous engagement is maintained
on the rod at all times by the take-up device, enabling the rod
system to perform as designed from the time of installation.
FEATURES:
• Maintains rod-system tightness, enabling it to perform as designed
• Pass-through design provides unlimited shrinkage compensation
• Available for
3
8" and
1
2" diameter threaded rod
• Fastens easily to the wood plate with the BPRTUD3-4
bearing plate and (2) 8dx1
1
2" nails (minimum) or (2)
#9x1
1
2" Strong-Drive
®
SD structural-connector screws
INSTALLATIONS:
• See the General Notes in the Simpson Strong-Tie
®
Wood Construction Connectors catalog.
• RTUD3 and RTUD4 must be installed with the BPRTUD3-4 bearing
plate (sold separately) to function properly within a rod system
• Additional instructions on back page
CODES:
ICC-ES ESR-2320
RTUD4 (RTUD3 Similar)
(Patent Pending)
RTUD Ratcheting Take-Up Device
BPRTUD3-4
(Sold Separately)
1. ATR: all-thread rod tensile capacity shown is for ASTM F1554
Grade 36, A36 or A307 standard steel, F
u
= 58ksi.
2. Thread specification for threaded rod must be UNC Class 2A, in accordance with ANSI/ASME B1.1.
3. No further increase in allowable load permitted.
4. Bearing plate loads based on
3
4" diameter hole through wood plate below steel
bearing plate. Modify allowable load per code for different hole size.
Model No.
Threaded
Rod Dia.
(in.)
Dimensions (in.)
Allowable
Load
(lbs.)
Seating
In c r em e n t
R
(in.)
Deflection
at Allowable
Load
A
(in.)
Length Width
Height
RTUD3
3
8 2
3
8 1
1
4
15
16 3335 0.053 0.015
RTUD4
1
2 2
3
8 1
1
4
15
16 6665 0.048 0.011
Model No.
Length
(in.)
Width
(in.)
Thickness
(ga.)
Allowable Loads (lbs.) (100/160)
4
½" Dia.
ATR
1
(lbs.)
" Dia.
ATR
1
(lbs.)
DF SP SPF
BPRTUD3-4 3 3 3 5965 5390 4055 4270 2400
© 2012 Simpson Strong-Tie Company Inc. F-RTUD12 10/12 exp. 12/14
1. Allowable loads are for RTUD only. The attached components must be designed to
resist design loads in accordance with the applicable code. See table below.
2. Thread specification for threaded rod must be UNC Class 2A, in accordance with ANSI/ASME B1.1.
3. No further increase in allowable load permitted.