Specification

C-2013 © 2013 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/12
157
Plated Truss Connectors
GBC
Gable Brace Connector
Plated Truss Connectors
Gable End
Truss
Wall
Top
Plate
Gable Brace
Flush at
Inside Edge
of Plates
2"
min.
Gable
Brace
Typical Sloped Installation
Example:
Gable Brace
Cut Diagram
2x4
Gable Brace
H = 2
15
16"
STEP 1
Double angle cut the gable brace
to sit flat on the wall double top
plate and flush against the gable
end truss for 2x4 top plate. The
double angle cuts should form
a 90° angle on the end of the
gable brace.
Gable End
Truss
STEP 2
Set each GBC on top of the
double top plate so that the
bend line slots are flush
with the inside edge of the
double top plate. Install
fasteners into the top of the
double top plate.
STEP 3
Bend GBC legs (one time
only) over the inside of the
double top plate and install
fasteners.
STEP 4
Install fasteners into the
gable brace.
NOTE: Attach the other end
of the gable brace to blocking
at the roof diaphragm as
directed by the Designer.
The GBC provides a proven, tested connection for the anchorage of
building stability bracing to the top of the gable end wall. With allowable
bracing installation angles between 40° to 60°, the GBC offers greater
flexibility in a connector rated for both tension and compression loads.
MATERIAL: 16 gauge
FINISH: Galvanized
INSTALLATION:
•Useallspecifiedfasteners.SeeGeneralNotes.
•TheGBCmustbeinstalledinpairstoachievefullloadcapacity.
CODES: See page 13 for Code Reference Key Chart.
GBC INSTALLATION SEQUENCE
Typical GBC Installation
1. For 1
3
4
x 3
1
2
(or larger) LVL gable brace, the allowable load at 40° to 45° is 635 lbs. towards anchors,
515 lbs. away from anchors.
2. Loads have been increased 60% for wind or earthquake loading with no further increase allowed;
reduce where other loads govern.
3. Use a minimum 2x4 gable brace. Larger members may be used.
4. NAILS: 8d = 0.131" dia. x 2
1
2
" long, 8dx1
1
2
= 0.131" dia. x 1
1
2
" long.
See page 22-23 for other nail sizes and information.
Model
No.
Qty
Req’d
Fasteners
per
Connector
DF/SP Allowable Loads (160)
Perpendicular to Endwall (F
2
)
SPF/HF Allowable Loads (160)
Perpendicular to Endwall (F
2
)
Code
Ref.
Toward GBC Away from GBC Toward Anchors Away from Anchors
Gable
Brace
Top
Plates
Gable Brace Angle Gable Brace Angle Gable Brace Angle Gable Brace Angle
40°-4 46°-60° 40°-4 46°-60° 40°-4 46°-60° 40°-4 46°-60°
GBC 2 5-8dx1
1
2
7-8d 635 570 425 325 535 480 355 275 I13, F12
Slope
H
Dimension
40° 2
15
16
50° 3
1
16
60° 3
9
16
This product is preferable to similar connectors because of
a) easier installation, b) higher loads, c) lower installed cost,
or a combination of these features.
GBC
US Patent
7,788,873;
5,603,580

Summary of content (1 pages)