INSTALLATION INSTRUCTIONS
1. Bypass ballast by cutting all wires as in Fig. 1
2. Replace shunted lamp holder with non-shunted one if applicable (Instant Start)
3. Directly wire Live + Neutral on a single end as in Fig. B for single tube or as in Fig. 3
for multiple tubes
Wiring diagram for removing electronic ballast and AC
remove electronic ballast and AC connection
Cautions:
1. This product is rated for indoor use only. Suitable for used in damp, dry, and enclosed xture applications.
2. Ballast bypass required. Use non-shunted LED tombstones on one end to direct-wire the tube.
3. This LED T8 is single-end powered. Can work with 100-277V AC power directly.
4. Non-Dimmable. Do not use with dimmer switches.
5. Make sure power supply is shut off when the product is installed.
6. This device should be installed by a qualied electrician or technician in accordance with relevant local codes.
Directly links to AC power (no ballast needed)