Off-Grid 
The Sol-Ark automatically operates in Off-Grid mode when it does not detect a grid connection. 
In an Off-Grid system setup, all the home’s loads are connected to the Sol-Ark’s Load Output (50A double-pole 
breaker). 
Do not use the Sol-Ark’s Grid Sell and Limited to Home modes in an off-grid system setup. 
Check the Limited power to load box in the Limiter tab of the Sol-Ark’s Grid Setup / Grid Param menu to allow 
for the batteries’ power to discharge to the connected loads. 
Generators 
The Sol-Ark’s built-in Auto Generator Start functions as a 2-wire automatic switch. 
The Sol-Ark’s Grid Input breaker can be used as the generator’s input breaker. In this scenario, check the 
General Standard box and the GEN connect to Grid input box in the Grid Param menu’s Sell Control tab:  
Figure 8 – Sell Control Tab in Grid Setup menu 
Due to the fact that many generators’ output frequency is usually less precise than the grid’s, the frequency 
parameters in the 
Grid Param menu’s Grid Input tab may also need adjustment to accommodate a wider 
frequency range: 
Figure 9 – Grid Input Tab in Grid Setup menu 