Installation
REV073019
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 25 |
Figure 12.0 – Inverter Enabled Display
To disable the inverter:
On the inverter information panel, simultaneously press the STARTUP/ SHUTDOWN button and
the Equalize button. The Conext XW Pro or XW+ is now disabled, and “diS” (disabled) is briefly
displayed on the inverter information panel, followed by "- - -".
Figure 13.0 – Inverter Disabled Display
Monitor the invert (green kW) LED to confirm which mode the inverter is in:
• kW LED OFF – Invert mode is disabled. The inverter/charger is not powering the AC loads.
However, if good AC is present, it is passed through to the loads.
• “Sch” displayed on the inverter information panel – The inverter/charger is in search mode
and is looking for an AC load greater than the Search Watts setting (default = 25 watts). The
display shows “Sch” (Search) when this mode has been enabled.