Installation
REV073019
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 19 |
AC Coupled System
CAUTION: Confirm the coupled grid-tie inverter’s compatibility with Schneider’s Conext XW Pro or
Conext XW+ prior to installation.
4.5.2 – Making AC Connections
AC Landing Points – Terminal Blocks
The SimpliPhi Access is equipped with multiple knockouts on either side of the AccESS for
accessibility to the AC connections. All AC connections are at 240 V. Please refer to Schneider
Electric’s Conext XW Pro or Conext XW+ Installation Manual for 120 V installations.
The Mini PDP has landing points for:
• AC IN: grid input
• AC OUT: home subpanel, optional AC coupled PV
Figure 7.0 below indicates the locations where AC IN and AC OUT wiring will be connected. Also
highlighted are the neutral and ground AC terminal blocks.
(3) PHI 3.8
BATTERIES
11.4 kWh, 5.7 kW