SimpliPhi Battery Manual
Table Of Contents
- PHI 3.8-MTM Battery Models
- and gain control of your own power.
- SimpliPhi Power helps you manage your power as a personal resource.
- power generation source – solar, wind, generator – on or off grid, and protects your home and mission-critical business functions from power outages and
- constraints, toxic coolants and the risk of thermal runaway. Safe lithium ferrous phosphate (LFP). No cobalt. No toxic hazards.
- (BMS) to create a portfolio of high performance, scalable and enduring energy storage solutions that provide power security, resilience and daily cycling for savings on your utility bill – all with a 98% efficiency rate.
- Table of Contents
- 1.0 – Introduction
- 2.0 – Safety
- 3.0 – Pre-Installation
- 4.0 – Installation
- 5.0 – Programming
- 6.0 – Troubleshooting
- Appendix A – PHI Battery Safety & Green Attributes,
- Appendix B – PHI Battery Bank Sizing Guide
- Appendix C – PHI Approved External Chargers
- Appendix D – PHI Legacy Battery Parameters
SIMPLIPHIPOWER.COM | 805-640-6700
REV202203161300
27
© SIMPLIPHI POWER, INC.
8. Check that all parameters in the Balance of System equipment are programmed according to the relevant SimpliPhi
Integration Guide. Failure to do so will damage the PHI batteries and Void the Warranty.
9. To charge the batteries quickly, SimpliPhi recommends using an AC power source to immediately charge the PHI battery
bank via the inverter’s charger. However, the PHI batteries will not incur any damage if they are charged using a connected
solar PV array via the charge controller. The important aspect of this step is that the batteries re-charge as soon as the BMS
has re-set.
10. Turn on the inverter’s AC Input breaker and turn on the inverter.
11. The inverter should automatically self-initiate a battery charge. However, a Force Charge may need to be initiated in the
inverter.
*This process can be duplicated with PHI battery models that do not include built-in breakers. To re-set the BMS on the PHI
battery models that are equipped with Anderson Connectors, disconnect the PHI Battery at the Anderson Connector instead of
the built-in breaker.