Victron Energy Integration Guide

REV070219
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93023, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 11 |
4.5 MPPT Settings
The program settings for the PHI 3.8 Batteries with Victron MPPT products are outlined below.
Table 4.0 - Settings for SimpliPhi PHI 3.8 kWh 48V Battery w/Victron MPPT
MPPT Solar Charge Controllers
10k Cycles
(80% DoD)
5k Cycles
(90% DoD)
3.5k Cycles
(100% DoD)
Battery Voltage
48V
Max Charge Current (C/2)
1
37.5A per PHI3.8; (75A for 2, 112.5A for 3)
Default Charge Settings
OFF
Absorb Voltage
54.4V
54.4V
56V
Absorb Time
1 Hour
Float Voltage
54V
Equalization Voltage
54V
Auto Equalization
OFF
Temperature Compensation
OFF
Notes:
1. Per PHI 3.8 Battery These settings are calculated by multiplying the nominal per battery value times the #
of batteries.
Levels are typical @ 25°C and may need adjusting at temperature extremes.
When performing rapid deep charge/discharge cycles, the PHI Battery should be allowed to "rest" 15 minutes
in between.