Samlex Integration Guide
REV070219
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 7 |
3.2 – Inverter Settings
Table 1.0 – Settings for SimpliPhi PHI 24V / 12V Batteries w/Samlex EVO Inverters
Samlex EVO
Settings
10K Cycles Warranty
5K Cycles
Warranty
3.5K Cycles
Warranty
Parameter Setup:
Charge Curve
80% DoD
90% DoD
100% DoD
1. Bulk Current
45 ADC per PHI 3.8-24V battery
45 ADC per PHI 2.9-24V battery
28.5 ADC per PHI 1.4-24V battery
14 ADC per PHI 730-24V battery
40 ADC per PHI 1.4-12V battery
28.5 ADC per PHI 730-12V battery
2. Absorp Voltage
27.2 V / 13.6 V
27.2 V / 13.6 V
28 V / 14 V
3. Equalize Voltage
N/A (disabled in Screen #12)
4. Float Voltage
N/A (2 Stage Type 1 Charging Profile set in Screen #21)
5. Compensate
To disable Compensation, set Battery Type to Lithium (Screen #22) and/or
do not plug in the Battery Temperature Sensor
6. Batt Over Volt
30 V / 15 V
7. Reset Voltage
26.7 V / 13.4 V
8. Low Volt Alarm
25.2 V / 12.6 V
24.9 V / 12.5 V
24.1 V / 12.1 V
9. Batt Low Voltage
25.1 V / 12.5 V
24.8 V / 12.4 V
24 V / 12 V
10. LV Detect Time
10 sec
11. LV Cut Off Time
1200 sec
12. Equalize-4Stages
0 = No
13. Mode
1
0 = Normal (Offline)
1 = Online (effective only when Screen #14 Online Option is set to 1)
2 = Charger Only (the inverter/charger will charge the batteries and pass
through the AC input power to the loads as long as AC input is available)
14. Online Option
2
0 = Option 1
1 = Option 2
15. Reset to Bulk
N/A (charging is never in Float Stage)
16. GS Detect Time
10 sec
17. Gen On Time
60 min
18. Gen Off Delay
Varies according to battery bank size and desired generator runtimes.
19. Absorp Time
60 min
20. Absorp Exit Amps
N/A (setting applies to 3-stag charging, not 2-stage)
21. Charging Profile
3 = 2 Stage Type 1
22. Battery Type
1 = Lithium
Notes:
• 1. Refer to page 48 of the EVO-RC-PLUS manual for more Mode details.
• 2. Details regarding the two Online Options are described on page 50 of the EVO-RC-PLUS manual
• Levels are typical @ 25⁰C and may need adjusting at temperature extremes.
• When performing rapid deep charge/discharge cycles the battery should be allowed to "rest" 15 minutes in between.
• Always refer to the SimpliPhi Power Manual and Warranty for the specific PHI battery model.
CAUTION: When PHI battery quantities change, the capacity & charge/discharge current settings
must to be reassessed. Failure to do so will void the Warranty.