3.0 Program Settings for PHI Batteries
In order to maintain the Warranty, it is critical to ensure that the appropriate settings for the desired Warranty
are programmed in all of the system components. This section will cover the basic concepts and settings
for Samlex equipment.
3.1 Depth of Discharge
In order to optimize performance and the life of your system and PHI batteries, SimpliPhi Power
recommends programming the equipment settings for 80% Depth of Discharge (DoD). This qualifies for
the SimpliPhi 10-year / 10,000 cycle Warranty on the batteries. Greater DoD is possible but will result in
reduced cycle life.
CAUTION: If a firmware update is executed on Samlex equipment, ALL the settings must be
reverified. The programmed settings shown in the following tables must be applied based on
desired Warranty/cycle life. The recommended is 80% depth of discharge.