Victron Energy Integration Guide
REV050918
SimpliPhi Power, Inc. | 420 Bryant Circle | Ojai, CA 93023, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 11 |
4.5 – MPPT Settings
The program settings for the PHI 3.5 Batteries with Victron MPPT products are outlined below.
Table 4.0 - Settings for SimpliPhi PHI 3.5 kWh 48V Battery w/Victron MPPT
MPPT Solar Charge Controllers
10k Cycles
(80% DoD)
5k Cycles
(90% DoD)
3.5k Cycles
(100% DoD)
Battery Voltage 48V
Max Charge Current (C/2)
1
34A per PHI3.5; (68A for 2, 102A for 3)
Default Charge Settings OFF
Absorb Voltage 56V 57.6V 57.6V
Absorb Time 6 Minutes
Float Voltage 54V
Equalization Voltage 54V
Auto Equalization OFF
Temperature Compensation OFF
Notes:
1. Per PHI 3.5 Battery – These settings are calculated by multiplying the nominal per battery value times the #
of batteries.
Levels are typical @ 25°C and may need adjusting at temperature extremes.
When performing rapid deep charge/discharge cycles, the PHI Battery should be allowed to "rest" 15 minutes
in between.
Always refer to the SimpliPhi Power Manual and Warranty for the specific PHI Battery model.