4.2 – Charge Controller Settings
Please review Table 2.0 below for Midnite Solar charge controller program settings. To initiate a factory
reset, hold left & right arrow buttons while turning on Battery Breaker. This is normally only done for initial
setup, as doing so will erase all custom settings.
Table 2.0 - Settings for SimpliPhi PHI 2.7 & 3.5 kWh Batteries w/ Midnite Solar Charge Controller
CHARGE CONTROLLER PHI 2.7 kWh & 3.5 kWh; 24V / 48V
Setting
10k Cycles
(80% DoD)
5k Cycles
(90% DoD)
3.5k Cycles
(100% DoD)
Charging Source
Source
Solar / Wind / Hydro
Battery Voltage (V)
24 / 48
Charge
Battery Charge Setpoints
Volts
EQ (V)
27.8 / 55.4
28.4 / 57.2
28.4 / 57.2
Absorb (V)
27.8 / 55.4
28.4 / 57.2
28.4 / 57.2
Float (V)
27.8 / 55.4
28.4 / 57.2
28.4 / 57.2
ChgTime
Absorb Minimum (Hrs:Mins)
0:01
Absorb Maximum (Hrs:Mins)
0:06
EQ
0 (Disabled)
T-Comp
Comp (mV/°C/cell)
0 (Disabled)
EQ Comp'd
NO
EQ
Auto EQ
0 (Disabled - shows "Manual interval")
End Amps
3
Ending Amps (A)
4 / 2
Re-Bulk Voltage (V)
25.3 / 50.6
Limits
Output Amps
1,2
45A per PHI2.7 24V; 26A per PHI2.7 48V
45A per PHI3.5 24V; 34A per PHI3.5 48V
Input Amps
1
Size based on input charging source
Min T-Comp
N/A (Disabled)
Max T-Comp
N/A (Disabled)
Mode
Battery Charge Setpoints
On/Off
ON
Mode
Hydro / Solar / Legacy P&O / Wind Track / Dynamic / U-Set Voc%
AUX 1
Manual Off
AUX 2
3
Manual Off
Notes:
1. Per PHI battery Refer to Section 3.0 herein for charge controller PHI battery bank sizing.
2. Per PHI battery These settings are calculated by multiplying the nominal value per each PHI battery times
the # of PHI batteries. For other batteries, refer to the Warranty and Specification Sheet for the specific model.
3. End Amps settings only work when the “Midnite Whiz Bang Jr & 500A/50mV shunt” are installed. When the
Whiz Bang Jr is used, Aux 2 is not available for a turn off signal from auxiliary source.
Levels are typical @ 25°C and may need adjusting at temperature extremes.
When performing rapid deep charge/discharge cycles, the PHI battery should be allowed to "rest" 15 minutes in
between.
Always refer to the SimpliPhi Power Manual and Warranty for the specific PHI battery model.
CAUTION: When PHI battery quantities change, the capacity & charge/discharge current settings