8. Check that all parameters in the Balance of System equipment are programmed according to the relevant SimpliPhi
Integration Guide. Failure to do so will damage the PHI batteries and Void the Warranty.
9. To charge the batteries quickly, SimpliPhi recommends using an AC power source to immediately charge the PHI battery
bank via the inverter’s charger. However, the PHI batteries will not incur any damage if they are charged using a connected
solar PV array via the charge controller. The important aspect of this step is that the batteries re-charge as soon as the BMS
has re-set.
10. Turn on the inverter’s AC Input breaker and turn on the inverter.
11. The inverter should automatically self-initiate a battery charge. However, a Force Charge may need to be initiated in the
inverter.
*This process can be duplicated with PHI battery models that do not include built-in breakers. To re-set the BMS on the PHI
battery models that are equipped with Anderson Connectors, disconnect the PHI Battery at the Anderson Connector instead of
the built-in breaker.