- AmpliPHI 3.8 Battery
- 3.8 kWh DC @ 100% DoD
- Rated kWh Capacity per Battery
- 3.04 kWh DC @ 80% DoD (recommended)
- 37.5 Amps DC (1.9 kW DC)
- MAX Continuous Discharge Rate
- 4.0 – Program Settings for PHI Batteries
- 5.0 – Use Cases & Application Notes
- 6.0 – Specifications & Warranty
- 7.0 – SimpliPhi Power Technical Support
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
|
11
|
© SIMPLIPHI POWER
Checking the BMS Lithium Batt box in the Batt Setup menu’s “Batt” tab first will auto-populate all values
communicated from the AmpliPHI batteries to the Sol-Ark (see Figure 8 below). These auto-populated
parameters will include:
• Batt Capacity (Battery Setup Batt menu)
• Max A Charge (Battery Setup Batt menu)
• Max A Discharge (Battery Setup Batt menu)
• TEMPCO (Battery Setup Batt menu)
• A (referring to Gen/Grid Charge Amps in the Battery Setup Charge menu)
• Float V (Battery Setup Charge menu)
• Absorption V (Battery Setup Charge menu)
• Equalization V / days / hours (Battery Setup Charge menu)
Fi
gure 8: BMS Lithium Batt Box to be Checked First
REV202105181844
00