Owner`s manual

9
SimpliFire • SF-WM36 • 2040-902 Rev. F • 1/14
Figure 4.6 Installing Anchors in Hollow Wall
Figure 4.4 3/16 Toggle-Bolt Anchor
Four 3/16 toggle-bolt anchors are provided to ac-
comodate four of the six required anchor points. Use
of toggle bolt anchors requires drywall thickness of
minimum 1/2 in.
Insert the bolt through the front side of the mounting
bracket and thread the toggle onto it from the rear of
the bracket. See Figure 4.5.
Fold the toggle wings ush against the bolt and push
them through a drilled hole until they expand open
on the other side. See Figure 4.6.
Pull back on the bolt and tighten. See Figure 4.4.
Note: This product cannot be installed on a wall
sheathed with drywall less than 1/2 in. thick, unless
all six anchor points in the mounting bracket align
with structural framing members.
WARNING! Risk of Damage or Personal Injury! Al-
lowable pull-out and shear strength are 25% of ultimate
values or less, as required by building authorities.
Framed Wall
For each of the marked anchor point locations, de-
termine which points align with a structural framing
member.
At the points where a wood or metal framing mem-
ber exists, the 5 x 40 screw can be installed directly
into that structural member. See Figure 4.3.
Every mounting hole that does not align with a
structural framing member, a wall board toggle-bolt
anchor must be used. See Figure 4.4.
Figure 4.5 Toggle Bolt Installation through Mounting Bracket
C. Appliance Installation
Hang appliance on the mounting bracket.
Align the slots on the back of the appliance with the
hooks on the top two corners of the bracket.
Hang the appliance and pull down to ensure the hooks
are fully engaged. See Figure 4.7.
Secure the appliance to the bracket with two M5x10
screws. See Figure 4.7.
1
2
Secure with screw on each
side of appliance.
Figure 4.7 Attaching Fireplace to Bracket
Mounting Hooks
Point Up