D. Location
When choosing a location for your replace ensure that
the general rules are followed:
• For best results, install out of direct sunlight.
• Power supply service must be installed within
proximity of electric replace prior to nishing to
avoid reconstruction.
E. Clearance to Combustibles
Minimum Clearance to Combustibles
Sides.......................0 in.
Floor........................0 in.
Top..........................0 in.
Back........................0 in.
Front.......................36 in.
Mantels..........See Figure 3.1
WARNING! Risk of Fire! Keepelectricalcords,drapery,
furnishings or other combustibles at least 3 ft. (0.9 m)
fromthefrontoftheelectricreplace,andawayfromthe
sidesorrear.
F. Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have
adequate electric power. A 15 AMP, 120V/60hz. circuit
is required. Additional appliances on the same circuit as
this heater may exceed the current rating of that circuit.
A dedicated circuit is not required, but is preferred to
prevent circuit breaker trips or fuse failure.
Reference Section 4.E for more complete detail on com-
pleting electrical installation.
2 in.
2 in.
2 in.
6 in.
12 in.
Measurements from top surface
of the door front.
Figure 3.1 Minimum Vertical and Maximum Horizontal Dimensions of Combustible Mantels.