Specifications
set log
Chapter 23
System Log Commands
627
sessions Sets the default log values for Telnet sessions. You can set
defaults for the following log parameters:
• Severity
• Logging state (enabled or disabled)
To override the session defaults for an individual session,
type the set log command from within the session and use
the current option.
trace Sets log parameters for trace files.
port port-number Sets the TCP port for sending messages to the syslog server.
You can specify a number from 1 to 65535. The default
syslog port is 514.
severity
severity-level
Logs events at a severity level greater than or equal to the
level specified. Specify one of the following:
• emergency—The UNIVERGE WL Controller is
unusable.
• alert—Action must be taken immediately.
• critical—You must resolve the critical conditions. If the
conditions are not resolved, the UNIVERGE WL
Controller can reboot or shut down.
• error—The UNIVERGE WL Controller is missing data
or is unable to form a connection.
• warning—A possible problem exists.
• notice—Events that potentially can cause system
problems have occurred. These are logged for diagnostic
purposes. No action is required.
• info—Informational messages only. No problem exists.
• debug—Output from debugging.