Specifications
show system
Chapter 4
System Services Commands
42
Fan status Operating status of the three WL5100 cooling fans:
• OK—Fan is operating.
• Failed—Even as for 1 in three fan in the case of not operating.
UNIVERGE WL Control System sends an alert to the system
log every 5 minutes until this condition is corrected.
Fan 1 is located nearest the front of the chassis, and fan 3 is
located nearest the back.
In the case of WL1700-MS, nothing is displayed.
Temperature Status of temperature sensors at three locations in the WL5100:
temp1
• ok—Temperature is within the acceptable range of 5° C to
100° C (32° F to 212° F).
• ng—Temperature is above or below the acceptable range.
temp2
• ok—Temperature is within the acceptable range of 0° C to
60° C (41° F to 140° F).
• ng—Temperature is above or below the acceptable range.
• Alarm—Temperature is above or below the acceptable range.
UNIVERGE WL Control System sends an alert to the system
log every 5 minutes until this condition is corrected.
SCA-WL10
WL1700-MS
PSU Status
Status of the one power supply units in the SCA-WL10 and
WL1700-MS:
• DC ok—Power supply is producing DC power.
• DC output failure—Power supply is not producing DC power.
UNIVERGE WL Control System sends an alert to the system
log every 5 minutes until this condition is corrected.
• AC ok—Power supply is receiving AC power.
• AC not present—Power supply is not receiving AC power.
Table 2. show system Output
Field Description