Freestanding Woodstove Owners & Installation Manual www.regency-fire.com MODEL: Tested by: 219-S-18-2 919-336 F3500 Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St.
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fire may result.
TABLE OF CONTENTS Safety Label for F3500 ..................................................4 Unit Dimensions ............................................................5 Residential Installation...................................................6 Modular Installation Options ..........................................6 Room Air - Important .....................................................6 Stove Assembly Prior To Installation .............................7 Minimum Clearance To Combustible Materials ....
SAFETY LABEL This is a copy of the label that accompanies each Regency Freestanding Woodstove (F3500). We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
DIMENSIONS UNIT DIMENSIONS 15-1/16" 8-7/8" [225mm] 26" [660mm] 12-7/8" 32-7/8" [865mm] 36" [914mm] 30-1/4" [768mm] 24-7/16" [621mm] 23" [584mm] F3500 Regency Freestanding Woodstove 22" [559mm] 5
INSTALLATION RESIDENTIAL INSTALLATION 1) Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspector. 2) Select a position for your Regency Stove. Consult the minimum clearance chart for your model and set the stove in place. For installation use listed double wall connector systems only.
INSTALLATION STOVE ASSEMBLY PRIOR TO INSTALLATION The F3500 unit requires the pedestal attached to the base. The F3500 stove requires either the Airmate or Rear Heat Deflector on top of the stove. Clearances to combustible materials vary depending on whether the airmate or rear heat deflector is installed, so be sure to check the Minimum Clearances, Installation section.
INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the Airmate or the Rear Heat Deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Clearances may only be reduced by means approved by the regulatory authority.
INSTALLATION WALL EXIT CLEARANCE FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer.
INSTALLATION MASONRY FIREPLACE There are listed kits available to connect a stove to a masonry fireplace. The kit is an adapter that is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation. Minimum vertical of 36" before any offset. Horizontal Maximum of 36" with 1/4" rise per foot. NOTE: Recommend using 2-45º instead of 90º to improve draft and performance. Single Double 6" 18" [457mm] [152mm] Min. 36" Vertical Rise Max.
INSTALLATION COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS Minimum chimney clearance to brick and combustibles 2 in. (50.8mm) Method A: 12" (304.8 mm) Clearance to Combustible Wall Member: Method B: 9" (228.6 mm) Clearance to Combustible Wall Member: Chimney Flue Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its equivalent.
INSTALLATION FLOOR PROTECTION A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 8" (203mm) from each side and minimum 16" (406mm) from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove.
INSTALLATION STEP-BY-STEP CHIMNEY AND CONNECTOR INSTALLATION Note: These are a generic set of chimney installation instructions. Always follow the manufacturers own instructions explicitly. Verify the Minimum Recommended Heights for Woodstove Flue (Table 1 in the Installation section). 1. With your location already established, cut and frame the roof hole. It is recommended that no ceiling support member be cut for chimney and support box installation.
INSTALLATION RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft (refer to Table 1). 3) Add 4% overall for each 1000' above sea level. 1) At sea level minimum height is 12' straight. Example: a) 1-1/2 ft. of horizontal run one "T" Total Addition (at sea level) = 3 ft. = 3 ft. = 6 ft. Example: b) One 90 deg. elbow 2 ft. of horizontal run one "T" Total Addition (at sea level) = 2 ft. = 4 ft. = 3 ft. = 9 ft. 2) Add the following vertical height to compensate for: 45 deg. elbow = 1 ft. 90 deg.
INSTALLATION MOBILE HOME INSTALLATION In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home. For Canadian Installations: see Outside Air Kit Blanking Plate - Part # 042-909 There are futher requirements when installing this unit into a mobile home in Canada Only. 1. The stove must be permanently bolted to the floor of the Mobile Home using the floor screws provided.
INSTALLATION OPTIONAL OUTSIDE AIR KIT The Outside Air Kit is an option for Freestanding Stoves. Outside air for combustion can be brought in either through the bottom of the pedestal or bottom heat shield or through the rear plate of the pedestal. For both bottom and rear outside air the Pedestal Cover Plate must be installed. Loosen the 4 screws on the rear of the pedestal and slide the cover plate over them. Slide the plate to the left to center it and tighten down the 4 screws.
INSTALLATION LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Regency F3500 Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used. NOTE: Required double wall chimney connector must be in good condition and kept clean. U.S. Installation* SELKIRK SURE-TEMP Qty.Part # Description 1 8T-FCK Flat Ceiling kit 1 8T-PCK Pitched ceiling kit 1 8ST-48 48" Chimney length (also in 6", 9", 12", 18", 24", 36" lengths. PROJET Nova Temp Qty.
INSTALLATION STAINLESS STEEL SMOKE DEFLECTOR INSTALLATION / REPLACEMENT: The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts. Smoke deflector installed with 2 bolts. Note: This is a view from inside the firebox looking out. Smoke deflector To replace the deflector, loosen off both bolts and slide defector upward and out.
INSTALLATION BRICK INSTALLATION Firebrick is included to extend the life of your stove and radiate heat more evenly. Install all firebricks per the diagram below and place in their correct positions. Do not use a grate. 1. Remove box of firebricks from inside unit. 2. Remove Lyotherm sheet from mailer tube and install on base of firebox as shown below. Lyotherm sheet 3.
INSTALLATION REMOVABLE DOOR HANDLE The F3500 has a removable door handle that can be stored when not in use. Hook Handle The cool to touch door handle is designed to be inserted from the bottom up and slide off when not held in place. Once in position, the door can be opened. After use, store the door handle on the storage hook located on the left side of the faceplate WARNING: FAILURE TO USE REMOVABLE HANDLE AS PER INSTRUCTIONS MAY CAUSE SERIOUS BURNS.
INSTALLATION FAN INSTALLATION Fan assembly for use only with the room heater marked to indicate such use. FAN INSTALLATION (120V FAN) FAN OPERATION AUTOMATIC 1. Remove the two screws from the top of the fan housing. To operate the fan automatically, push the bottom switch on the side of the fan housing to "AUTO" and the top switch to either "HIGH" or "LOW" for fan speed. 2. Slide the fan up into the rear heat shield. 3.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your Catalytic combustor and draft control. WARNING Fireplace Stoves equipped with doors should be operated only with doors fully closed.
OPERATING INSTRUCTIONS INSTALLATION 16. The controls of your unit or the air supply passages should not be altered to increase firing for any reason. 17. If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can. An easy rule of thumb says that if your glass is clean, catalytic thermostat is active, then your flue is clean and your exhaust is clean.
MAINTENANCE DO NOT BURN: • Treated wood • • • • • • • • Coal Garbage Cardboard Solvents Colored Paper Trash Salt drift wood Cut lumber, plywood, mill ends. 14. Do not store any fuel closer than 2 feet from your unit. Do not place wood, paper, furniture, drapes or other combustibles near the appliance. 15. WARNING: Do not operate without either the Ash Plug properly seated or the Ash Dump Plates screwed in place, excessive temperatures will result. 16. CAUTION: Do not operate with broken glazing.
MAINTENANCE MAINTENANCE It is very important to carefully maintain your fireplace stove, including burning seasoned wood and maintaining a clean stove and chimney system. Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your stove require no lubrication. THERMOMETER The catalyst thermometer is only a indication of the flue gas temperature as they pass through the catalyst.
MAINTENANCE CATALYTIC COMBUSTOR ACHIEVING AND MAINTAINING CATALYST LIGHT-OFF: The temperature in the stove and the gases entering the combustor must be raised to between 500F to 700F for catalytic activity to be initiated. During the start up of a cold stove a medium to high firing rate must be maintained for about 30 minutes. This ensures that the stove, catalyst and fuel are all stabilized at proper operating temperatures.
MAINTENANCE COMBUSTOR ASSEMBLY REMOVAL / REPLACEMENT: NOTE: If also replacing the gasket in the bypass door (see next page), remove the lid of the bypass door while it is accessible and complete steps in Bypass Door Gasket Replacement. The catalytic thermometer on top of the stove should read in the active zone after the stove has been in operation for several hours.
MAINTENANCE BYPASS DOOR GASKET REPLACEMENT 1. Allow the stove to burn out and cool down, until cool to touch. 4. Slide bypass door assembly forward, lower complete assembly with care. Lift lid on bypass door assembly to reveal gasket. 2. Open stove door to access bypass door. 4. Remove old gasket and replace with new one. 3. Remove loosen the 3 rear bolts, then remove 3 front bolts. Support from the front and slide forward to remove Bypass Door Assembly.
MAINTENANCE SECONDARY AIR TUBE REMOVAL / INSTALLATION 1. Allow the stove to burn out and cool down, until cool to touch. 2. Open stove door to access secondary air tube. DOOR CATCH ADJUSTMENT The door catch may require adjustment as the door gasket compresses after a few fires. The door catch compression may require adjustment to renew seal. Removal of the spacer washer, shown in the diagram below, will allow the catch to be moved closer to the door frame, causing a tighter seal.
MAINTENANCE Annual Maintenance Completely clean out entire unit Annually Inspect air tube, Catalytic Combustor and bricks Replace any damaged parts. Adjust door catch assembly If unable to obtain a tight seal on the door - replace door gasket seal. Readjust door catch after new gasket installed. Inspect condition and seal of: Glass Gasket Door Gasket Perform paper test - replace gasket if required Paper Test Test the seal on the loading door with a paper bill.
PARTS LIST F3500 STOVE MAIN ASSEMBLY Part # 1 Description Part # Description Firebox assembly 8 051-018 Handle holder 9 042-520 Cast door assembly # 5 051-530 Catalytic Combustor Assembly (not shown) 2 846-515 Fan - free standing stove 3 042-912 Airmate - medium assembly 4 051-538 Removable arm assembly 033-953 Airtube 1" x 23" long 5 042-517 Rear Heat Shield Assembly 10 904-245 #10-16 x 1/2" SDS HEX HD 6 042-029 Classic side heat shield - RH 11 904-530 Screw 1/4-20 x 1/2
PARTS LIST F3500 STOVE BRICK LAYOUT 042-960 Brick Set Complete Fire bricks # Size 1 4-1/2" x 9" 2 2" x 9" 3 3-1/2" x 4-1/2" 4 1-3/4" x 4-1/2" 5 4-1/2" x 7-5/8" 6 1 5 32 4 3 1 2 F3500 Regency Freestanding Woodstove
PARTS LIST DOOR ASSEMBLY Part # Description 1 042-201 Door cast black (F3500) 2 106-541/P Aligner assembly 3 156-514 4 940-416/P 5 6 Part # Description 7 846-530 5/8" Medium Door gasket kit 8 042-021 Gasket bracket Removable cast handle assembly 9 904-513 Hex bolt 1/4-20 x 3/4 LG. Door glass 10 904-525 Washer 1/4" split lock 943-243 7/8" flat window gasket (per 5ft.
NOTES 34 F3500 Regency Freestanding Woodstove
NOTES F3500 Regency Freestanding Woodstove 35
NOTES 36 F3500 Regency Freestanding Woodstove
WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product. This warranty is not transferable.
WARRANTY APPLIED CERAMICS IMPORTANT WARRANTY INFORMATION FOR CATALYTIC CONVERTER Any and all claims for catalytic combustor must be filed by the consumer directly with APPLIED CERAMICS (full address below). FPI/Regency does not handle these claims. Please follow the instructions below for returning your catalytic converter under warranty. To learn more about the care and maintenance or the catalytic converter, please visit our website: www.firecatcombustors.com.
WARRANTY CANADIAN CUSTOMERS ONLY APPLIED CERAMICS IMPORTANT WARRANTY INFORMATION FOR CATALYTIC CONVERTER Any and all claims for catalytic combustor must be filed by the consumer directly with their authorized Regency Dealer. FPI/Regency does not handle these claims directly with consumers. Please follow the instructions below for returning your catalytic converter under warranty. To learn more about the care and maintenance or the catalytic converter, please visit our website: www.firecatcombustors.com.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.