Specifications

10
AC VOLTAGE OUTPUT CHECK v
1. Insert RED test lead into v receptacle in
meter.
2. Insert BLACK test lead into
COM
receptacle in
meter.
3. Rotate selector to position.
4. Attach RED test clip to alternator AC output
terminal(s).
5. Attach BLACK test clip to engine ground.
NOTE: When checking AC voltage output of stator
on 10-16 and 20 amp regulated or Quad-
Circuit alternator systems, attach one
meter test clip to each output pin terminal
in YELLOW connector from stator. Test clip
leads may be attached to either output pin.
6. With engine running at 3600 RPM, AC output
reading should be close to specification listed for
alternator type in Table 2.
AC Voltage Output Check
TABLE 2
ALTERNATOR
AC OUTPUT AT 3600 RPM
AC ONLY 14 VOLTS
DUAL CIRCUIT 14 VOLTS
• 5 AMP REGULATED 28 VOLTS
• 9 AMP REGULATED 40 VOLTS
TRI-CIRCUIT 28 VOLTS
QUAD-CIRCUIT 30 VOLTS
• 10 AMP REGULATED 20 VOLTS
• 16 AMP REGULATED 30 VOLTS
• 16 AMP REGULATED 26 VOLTS
• 20 AMP REGULATED 29 VOLTS
• 20-50 AMP REGULATED
5 VOLTS -
From each winding
• Alternator output is determined by, ywheel, alternator
and magnet size.
WHITE
CONNECTOR
DUAL
CIRCUIT
RED CLIP TO
AC SIDE OF
HARNESS
(BLACK WIRE)
TEST CLIP TO
AC OUTPUT PIN
TEST CLIP TO
A GOOD GROUND
SURFACE
WHITE
CONNECTOR
TEST
CLIP
GREEN
CONNECTOR
YELLOW
CONNECTOR
TEST
CLIP
ATTACH
METER
TEST
CLIPS
QUAD-CIRCUIT
10 AMP CIRCUIT
16 AMP CIRCUIT
9 AMP REGULATED
TRI-CIRCUIT
SINGLE CIRCUIT
AC ONLY