Specifications

– ECO ELITE FLUE OPTIONS
Vertical concentric flues – 80/125mm
Flue system G – Maximum permissible equivalent length =
20m. Any additional ‘in line’ bends in the flue system must
be taken into consideration. The equivalent lengths for
concentric pipes are: 135° bend – 0.5m, 93° bend – 1.0m.
Item description (MULTIFIT)
flue system G
Specification Key & OD
dimensions
Multifit sales
code
Vertical flue terminal 125mm 5111078
Vertical flue adaptor 125mm 5111070
Roof cover plate 125mm 246143
Flue bend 93˚ 125mm 5118588
Flue bend pair 135˚ 125mm 5118597
Flue extension 1000mm 125mm 5118584
Pipe support Painted white 125mm 5118610
Pitched roof flashing 25/50˚ 125mm 5122151
Flat roof flashing 125mm 246144
Horizontal concentric flues
– 60/100mm
Flue system A – Maximum permissible equivalent flue length
= 10m. Any additional ‘in line’ bends in the flue system
must be taken into consideration. The equivalent lengths for
concentric pipes are: 135° bend – 0.5m, 93° bend – 1.0m.
Item description (MULTIFIT)
flue system A
Specification Key & OD
dimensions
Multifit sales
code
Standard horizontal flue
inc elbow
685mm 60/100 5118489
Flue extension 1000mm 100mm 5111074
Flue bend 93˚ 100mm 5111075
Flue bend (pair) 135˚ 100mm 5111085
Flue bend 135˚ 100mm 5111076
Pipe support
Painted white
100mm 5111080
Flue through wall liner 100mm 5111067
Flue terminal deflector 60mm 5111068
Flue vertical adaptor (boiler) Main HE only 100mm 5111065
The 3° fall back on concentric flues can be reduced to 1.5° providing the flue
system is adequately clamped in accordance with the installation instructions.
Vertical concentric flues – 60/100mm
Flue system A – Maximum permissible equivalent flue length
= 10m. Any additional ‘in line’ bends in the flue system
must be taken into consideration. The equivalent lengths for
concentric pipes are: 135° bend – 0.5m, 93° bend – 1.0m.
Item description (MULTIFIT)
flue system A
Specification Key & OD
dimensions
Multifit sales
code
Vertical flue terminal 125mm 5118576
Roof cover plate 4” 125mm 246143
Flue bend 93˚ 100mm 5111075
Flue bend 135˚ 100mm 5111076
Flue bend pair 135˚ 100mm 5111085
Flue extension 1000mm 100mm 5111074
Pipe support
Painted white
100mm 5111080
Pitched roof flashing 25/50˚ 125mm 5122151
Flat roof flashing 125mm 246144
Flue vertical adaptor (boiler) Main HE only 100mm 5111065
Item description (MULTIFIT)
flue system N
Specification Key & OD
dimensions
Multifit sales
code
Twin pipe flue adaptor (boiler) 80/80mm 720089801
Twin to concentric adaptor
80/80 – 80/125
80/125mm 5111084
Twin pipe flue bend (pair) 90˚ 80mm 5111072
Twin pipe flue bend (2 pair) 135˚ 80mm 5111086
Twin pipe extension
(pair inc brackets)
1000mm 80mm 5111087
Twin pipe support (pair)
Painted white 80mm 5111081
Vertical flue terminal 125mm 5111078
Roof cover plate 100mm 246143
Pitched roof flashing 125mm 5122151
Flat roof flashing 25/50˚ 125mm 246144
Twin pipe flues – 80/80mm
Maximum permissible equivalent flue length = 20m. Any
additional ‘in line’ bends in the flue system must be taken into
consideration. The equivalent lengths for concentric pipes are:
135° bend – 0.25m, 90° bend – 0.5m.
Item description (MULTIFIT)
flue system G
Specification Key & OD
dimensions
Multifit sales
code
Standard horizontal flue
inc elbow
685mm 80/125 5118580
Flue extension 1000mm 125mm 5118584
Flue bend 93˚ 125mm 5118588
Flue bend (pair) 135˚ 125mm 5118597
Pipe support
Painted white
125mm 5118610
Horizontal concentric flues – 80/125mm
Flue system G – Maximum permissible equivalent length
= 20m. Any additional ‘in line’ bends in the flue system
must be taken into consideration. The equivalent lengths for
concentric pipes are: 135° bend – 0.5m, 93° bend – 1.0m.
The 3° fall back on concentric flues can be reduced to 1.5° providing the flue
system is adequately clamped in accordance with the installation instructions.
Plume displacement kits – 60/100mm
Item Description (MULTIFIT)
flue system K
Specification Key & OD
dimensions
Multifit sales
code
Plume displacement kit inc
elbow + clips
100mm 5118638
Plume displacement kit
extension + clips
1000mm 60mm 5121368
Plume displacement kit bend 93˚ 60mm 5121369
Plume displacement kit
bend (pair)
135˚ 60mm 5121370
Any additional ‘in line’ bends in the flue system must be taken into consideration.
Their equivalent lengths are:
Concentric flue
The maximum equivalent lengths are 4m (horizontal and vertical).
These lengths exclude the standard elbow and flue/terminal assembly
(horizontal) and terminal assembly (vertical).
Concentric pipes:
135° bend 0.5m
93° bend 1.0m
Twin flue
The total maximum equivalent flue length is 75m.
Note: Air and flue tubes parallel.
Twin flue pipe:
135° bend (air duct) 1.3m
135° bend (flue duct) 2.6m
90° bend (air duct) 4.8m
90° bend (flue duct) 9.6m
Detailed examples of equivalent flue length calculations are given in the Installation
Guidance Notes for each flue system type (Documents 243501 and 243502 for
concentric and twin pipe respectively).
G
G
Flue options
22
91529 A4 Main Range Brochure.indd 22 16/05/2014 14:30