Specifications

PHOENIX CONTACT 27
04.04.2008 12:53:42 Uhr04.04.2008 12:53:42 Uhr
inputs and
ted single-
UT1 and
derating)
accordance with
rdance with
IB IL 24 SDI 8-PAC
IB IL 24 SDO 8-PAC
IB IL 24 SDOR 4-PAC
Order No. 2985657
• Inline safety terminal with IP20 protection
Four safety-oriented two-channel inputs each,
or eight safety-oriented single-channel inputs
each
Two pulsed outputs for supply to the UT1 and
UT2 inputs
• Max. safety category 4 in accordance with
EN 954-1, PL e in accordance with
EN ISO 13849-1 and SIL 3 in accordance with
IEC 61508 (EN IEC 62061)
Order No. 2985754
• Inline safety terminal with IP20 protection
• Four safety-oriented two-channel outputs
each or eight safety-oriented single-channel
outputs each
• Max. 2 A (observe the derating)
• Max. safety category 4 in accordance with
EN 954-1, PL e in accordance with
EN ISO 13849-1 and SIL 3 in accordance with
IEC 61508 (EN IEC 62061)
Order No. 2985851
• Inline safety terminal with IP20 protection
• Two safety-oriented two-channel relays or
four safety-oriented single-channel relays (two
floating contacts each)
• Two readback inputs for recording external
circuit breakers and two pulsed outputs to the
readback inputs
• Max. safety category 4 in accordance with
EN 954-1, PL e in accordance with
EN ISO 13849-1 and SIL 3 in accordance with
IEC 61508 (EN IEC 62061)
IB IL 24 SDIO 4/4/1
IB IL 24 SAFE1-PAC
IB IL 400 SAFE 2
Order No. 2863740
Inline safety terminal with IP20 protection
Four safety-oriented two-channel inputs and
outputs each or eight safety-oriented single-
channel inputs and outputs each
Two pulsed outputs for supply to the UT1 and
UT2 inputs
Max. 2 A per output (observe the derating)
• One safety-oriented segment circuit output,
max. 6 A
Max. safety category 4 in accordance with
EN 954-1, PL e in accordance with
EN ISO 13849-1 and SIL 3 in accordance with
IEC 61508 (EN IEC 62061)
Order No. 2861564
• Inline safety terminal with IP20 protection
• Two safety-oriented inputs for direct
connection of emergency stop, safety door
and switching mat
• One safety-oriented segment circuit output,
max. 4 A
• Max. safety category 4 in accordance with
EN 954-1
Order No. 2740795
• Inline safety terminal with IP20 protection
• Three N/O outputs,
max. 12 A/600 V AC, 5500 VA
• Three N/O relay outputs,
max. 12 A/600 V AC, max. 5500 VA
• Max. safety category 4 in accordance with
EN 954-1