Specifications

Register Bit Descriptions
7-30
SEQ2 is irrelevant in cascaded mode.
At the start of an autosequenced session, SEQ_CNTR_n is loaded with the
value from MAX_CONVn. The SEQ_CNTR_n bits can be read at any time dur-
ing the countdown process to check status of the sequencer. This value, to-
gether with the SEQ1 and SEQ2 Busy bits, uniquely identifies the progress or
state of the active sequencer at any point in time.
Table 7–5. Status Bit Values for SEQ_CNTR_n
SEQ_CNTR_n
(read only)
Number of conversions remaining
0000 1
0001 2
0010 3
0011 4
0100 5
0101 6
0110 7
0111 8
1000 9
1001 10
1010 11
1011 12
1100 13
1101 14
1110 15
1111
16
Bits 7–4 SEQ2-State3 – SEQ2-State0
Reflects the state of SEQ2 sequencer at any point of time. If need be, user can
poll these bits to read “interim” results before an EOS. SEQ2 is irrelevant in
cascaded mode.
Bits 3–0 SEQ1-State3 – SEQ1-State0
Reflects the state of SEQ1 sequencer at any point of time. If need be, user can
poll these bits to read “interim” results before an EOS.