Specifications
Capture Units
6-67
Event Manager (EV)
Figure 6–27. Capture Units Block Diagram (EVA)
T2CNT
GP timer 2
counter
T1CNT
GP timer 1
counter
MUX
Edge
detect
2-level
FIFO
stacks
Cap FIFO
status
ADC start
CAPCONA[15]
CAP1,2,3
CAPCONA[8]
2
16
16
8
6
6
3
CAPCONA[9,10]
CAPCONA[12–14]
RS
clear
CAPCONA[2–7]
Edge
select
Capture unit 3
cap. event
CAPFIFOA[13–15]
RS