Operator`s manual
Operation
Simplicity Australia Page 3.30 Version 1.0
Step 1. Sketch secondary head position and plan the
positioning of the secondary head uptubes.
Step 2. Mount secondary head risers into position
Step 3. Fold the implement and check for clash points
Step 4. Mount primary dividers in position considering
that the secondary hoses should all be the same
length and no more than five metres long (refer
to examples below)
Step 5. Connect secondary hoses. Fold implement and
check that secondary hose doesn’t kink or foul on
fold lines
Step 6. Connect primary hoses. Fold implement and
check that the primary hose doesn’t kink or foul
on fold lines
Step 7. Attach secondary heads to risers
Step 8. Connect terminal hose, i.e. secondary head to
seeding boot.
The diagram on the left shows a primary
divider fitted at the centre rear of the
cultivator. In this example, with a wide
implement, the secondary hoses will be
far in excess of the recommended five
metres. In this case the primary dividers
should be moved out further onto the
implement, positioned as not to clash with
folding, and as shown in the example
below.
The diagram on the right shows the
primary divider positioned further
out on the implement resulting in the
secondary hoses being under the
recommended five metres. The
added advantage of correctly
positioning the primary dividers is
that less hose is used overall.
The terminal hose
when fitted sh
ould
not have excess
‘droop’ and should
be connected as
tight and as straight
as possible. Excess
‘droop’ can allow
product to collect in
the terminal hose
and possibly cause
blockages.
IMPORTANT
Secondary 8 meters
Primary Divider
Secondary Head
Assuming 6 x 2 way PD
• Total Secondary Hose used
is approximately 96 meters
• Total Primary Hose used is
approximately 18 meters
• Total hose to travel through
114m
3m
Secondary hose < 5 meters
Primary Divider
Secondary Head
Assuming 6 x 2 way PD
•
Total Secondary Hose used
is approximately 60m, (-36m )
• Total Primary Hose used is
approximately 30m, (+12m)
•Total hose to travel through
90m