Operator`s manual

3500 VRC Operator’s Manual
41
V5.00.26
October
2006
Revision M
Part No. : AM
-
Updated : 12/10/2006
6.3 Run/Hold Input
Master operation of the system can be controlled in a number of ways.
1. Run/Hold Input Disabled
Using the front panel “RUN/HOLD” key.
2. Run/Hold Input Clutch
This requires a connection to an external clutch switch that will activate the “RUN/HOLD” function
when operated. (Pin 20 on DB25)
3. Run/Hold Input 3704
This requires a connection to the 3704 remote bin run/hold switch box.
The Run/Hold input option can be toggled between “DISABLED” to use the front panel
“RUN/HOLD” key, “CLUTCH” to use the remote clutch switch (pin 20) or “3704” to use the 3704
remote bin run/hold switch box.
Refer to airseeder manufacturer’s guide for the recommended setting.
6.3.1 - Clutch
1. Press the softkey pointing at “RUN/HOLD INPUT”.
2. Using the arrow key change “DISABLED” to “CLUTCH”.
3. Press the “EXIT” softkey to escape to the main screen.
4. Turn the unit off then on again to activate the clutch input.
Note
Enabling the clutch input will disable the “RUN/HOLD” key on the front panel.