5.8 Pump 2 Speed (Liquid Tank Only)
The 3500VRC has two RPM inputs. Both of these inputs can be set up as either a Fan rpm input
(see 5.2 Fan RPM) or in the case of liquid a pump rpm input. The pump alarm warns the operator
when the pump rpm is outside the low and high set points. Two fan alarms are available. Enabling
the fan alarm displays live fan rpm on the main screen.
Pump alarms must be enabled before setting the pump low and high alarm points.
Note
Unlike Fan RPM, Pump RPM will NOT disengage drives when the Pump RPM falls below the low
alarm point. At any one time, only one Fan and one Pump, or two fans only, or two pumps
only can be used. (NOTE: Pump 2 reads in increments of 10rpm)
5.8.1- Enable Pump Alarm (Simplicity airseeder with liquid uses PUMP 2)
1. For a single pump press and hold for 3 seconds the softkey pointing at “PUMP 2”.
2. “DISABLED” will change to “ENABLED”. If Pump 2 is operating live pump rpm will be displayed.
3. Leave “PUMP 1” disabled.
5.8.2 - Set High and Low Points
1. Press the softkey pointing at “PUMP 2” until the pump 2 low alarm value is highlighted.
2. Use the arrows keys to enter the pump 2 low alarm point. Refer to manufacturer
recommended settings.
3. Press the softkey pointing at “PUMP 1” until the pump 2 high alarm value is highlighted.
4. Use the arrows keys to enter the pump 2 high alarm point setting. Refer to manufacturer
recommended settings.
After enabling the pump alarm, live rpm readings for one or both pumps will be displayed in the
alarms menu and main screen.
Note
For DC motor and hydraulic drives (HYD MFC, HYD PROP2, HYD DANFOSS, HYD DANFOSS L, HYD
PROP/XPRO) product metering will NOT stop if pump 1 or pump 2 rpm falls below the low alarm
points. At any one time, only one Fan and one Pump, or two fans only, or two pumps only
can be used.
Pump 2 reads in increments of 10rpm