5.6 - Depth Alarm (where fitted)
Provides a visual readout of implement ram position using a scale of 0 to 99. 0 is full ram extension
and 99 is maximum depth.
The depth alarm is set using a “HOLD” point, which automatically puts the unit on hold when the
implement is raised above this point. The depth sensor must be enabled before setting the hold
point.
1.6.1 Enable
1. Press the “NEXT>” softkey to display depth.
2. Press and hold for 3 seconds the softkey pointing at “DEPTH”.
3. “DISABLED” will change to “ENABLED”.
1.6.2 - Set Hold Point
When adjusting the implement height, the live reading provides a reference point for setting the
required hold point. Test the readout by raising and lowering the implement to ensure the depth
sensor is adjusted to provide a sufficient range of operation.
1. Press softkey pointing at “DEPTH” until the “HOLD” value is highlighted.
2. Using the live reading as a guide, adjust the implement height to display the required ‘hold’
point.
3. Use the arrow keys to set the “HOLD” point to match the live hold value.